ServMod Sign in

Supported equipment / Hitachi WJ C1

Hitachi WJ C1 parameter backup and restore from an Android phone

Back up the settings of a Hitachi WJ C1 on your phone, then restore them to a replacement drive in minutes. No laptop, no mobile signal and no software to install on a PC.

Tested on a drive Tested on a real drive over RS-485 and through the Box USB host. Direct phone USB does not work (probably a power problem).

Download free for AndroidAll wiring diagrams

How to connect it

  • USB-RS485 adapter on control terminals SP and SN (A/+ to SP, B/- to SN).
  • ServMod Box RS-485 channel to SP and SN, wireless to the phone.
  • ServMod Box USB host port to the micro-USB port under the keypad cover.

Terminal names differ between production batches. Check the names printed on your unit before you wire anything, and bench-test before you touch a production machine.

Wiring diagram: Hitachi WJ C1, 1 box usbWiring diagram: Hitachi WJ C1, 2 adapter rs485Wiring diagram: Hitachi WJ C1, 3 box rs485Wiring diagram: Hitachi WJ C1, 4 usb direct

What you can do with it in ServMod

  • Read all parameters and save them as a backup file on the phone. Free.
  • Compare a backup with a drive and see every difference. Free.
  • Watch live values and fault history, and look up fault causes. Free.
  • Edit parameters, restore a backup to a new drive, run the motor manually and reset faults. Part of the Pro plan.

Good to know

  • Reads 546 parameters (WJ200 parameter list).
  • Do not plug the phone straight into the micro-USB port: the drive loses the link right after connecting. Use the Box USB host or RS-485.
  • ServMod is an independent tool. It is not made, approved or supported by Hitachi.

Same brand: Hitachi WL200, Hitachi WJ200.

Using a different drive? Tell us which one you need. See also the cables and adapters you need.