Supported equipment
Every drive uses the same screens: Backup, Parameters, Control, Settings and Faults. Reading, backup and compare are free. Writing, restore and manual control are part of the Pro plan.
Inverters
| Drive | Connection | Status |
|---|---|---|
| Hitachi WL200 | USB cable (mini-USB) or USB-RS485 adapter | Tested on a drive |
| Hitachi WJ200 / WJ-C1 | USB-RS485 adapter on the RS-485 terminals, USB through the ServMod Box, or the phone's own USB port (WJ-C1) | Tested on a drive |
| Hitachi SJ200 | RS-485: USB-RS485 adapter or the ServMod Box. Register map from the manual. | Not yet tried on a drive |
| Allen-Bradley PowerFlex 520 / 525 | USB-RS485 adapter on the DSI port, or the ServMod Box | Tested on a drive (525) |
| Danfoss VLT FC 280 | USB cable, or USB-RS485 adapter on terminals 68 and 69 | Tested on a drive |
| Danfoss VLT FC 302 | USB cable or USB-RS485 adapter; USB through the Box is being tested. Read and backup checked on a drive; restore and factory reset not yet. | Partly tested |
| Danfoss VLT 2800 | USB-RS485 adapter on terminals 68 and 69 | Tested on a drive |
| Lenze 8400 StateLine C | CAN through the ServMod Box. A USB-CAN adapter (slcan) is coming and is not yet tried. | Tested on a drive |
| Omron 3G3MX2 (MX2-V2) | USB-RS485 adapter | Not yet tried on a drive |
| Mitsubishi FR-D700 | RS-485 adapter | Not yet tried on a drive |
| Mitsubishi FR-E800 | PU port RJ45 through an RS-485 adapter or the ServMod Box | Tested on a drive |
| Schneider ATV320 | RS-485 adapter, Modbus RTU | Not yet tried on a drive |
| Siemens SINAMICS V20 | RS-485 adapter on terminals P+ and N- (6 and 7) | Not yet tried on a drive |
| Delta MS300, INVT GD200A, ABB ACS355, Inovance MD500, Yaskawa GA500 | RS-485 adapter, Modbus RTU | Not yet tried on a drive |
More models and brands will follow. Tell us which drive you need on the requests page.
PLCs, read only
| Controller | Protocol | Notes |
|---|---|---|
| Omron | FINS over UDP, port 9600 | DM, CIO, W, H and A areas. Types WORD, INT, DWORD, DINT, REAL, BOOL. |
| Allen-Bradley Logix and Micro800 | EtherNet/IP, port 44818 | Read a tag by name. Optional CPU slot for Logix. |
| Mitsubishi | MC protocol | Planned. Usually needs a port opened in GX Works. |
Siemens is not supported: it needs the PUT/GET function unlocked in the controller. The PLC module is a draft and has been tested on a simulator only.
Control boards and panels
| Device | Connection | Status |
|---|---|---|
| Bilwinco Q20 control board | USB-RS232 adapter or the ServMod Box (Wi-Fi or Bluetooth) | Backup and restore checked on a board |
| Siemens OP17 operator panel | USB-RS232 adapter on the phone or in the ServMod Box | Write checked on spare panels |
Printers
Honeywell PM45 industrial thermal label printers, over Ethernet through a USB-C Ethernet adapter. The Cable check can also test the cable between the phone and any other network device.
Adapters
- RS-485: a USB-RS485 adapter with an FTDI, CP210x, CH34x or CH343 chip.
- Ethernet: any USB-C Ethernet adapter. Android handles it natively.
- One USB-C port: a phone has only one, so for Ethernet and RS-485 together use a powered USB-C hub.
- CAN: through the ServMod Box. Lenze 8400 is tested this way.
Device pages
- Hitachi WL200
- Hitachi WJ C1
- Hitachi WJ200
- Allen-Bradley PowerFlex 525
- Danfoss VLT FC 280
- Danfoss VLT 2800
- Lenze 8400 StateLine C
- Omron 3G3MX2 (MX2)
- Mitsubishi FR-D700
- Schneider ATV320
- Siemens SINAMICS V20
- Delta MS300
- INVT GD200A
- ABB ACS355
- Inovance MD500
- Yaskawa GA500
- Omron E5CN temperature controller
- Siemens OP17 operator panel
Wiring for each drive is on the wiring diagrams and the connection guides.