Supported equipment

Every drive uses the same screens: Backup, Parameters, Control, Settings and Faults. Reading, backup and compare are free. Writing, restore and manual control are part of the Pro plan.

Inverters

DriveConnectionStatus
Hitachi WL200USB cable (mini-USB) or USB-RS485 adapterTested on a drive
Hitachi WJ200 / WJ-C1USB-RS485 adapter on the RS-485 terminals, USB through the ServMod Box, or the phone's own USB port (WJ-C1)Tested on a drive
Hitachi SJ200RS-485: USB-RS485 adapter or the ServMod Box. Register map from the manual.Not yet tried on a drive
Allen-Bradley PowerFlex 520 / 525USB-RS485 adapter on the DSI port, or the ServMod BoxTested on a drive (525)
Danfoss VLT FC 280USB cable, or USB-RS485 adapter on terminals 68 and 69Tested on a drive
Danfoss VLT FC 302USB cable or USB-RS485 adapter; USB through the Box is being tested. Read and backup checked on a drive; restore and factory reset not yet.Partly tested
Danfoss VLT 2800USB-RS485 adapter on terminals 68 and 69Tested on a drive
Lenze 8400 StateLine CCAN through the ServMod Box. A USB-CAN adapter (slcan) is coming and is not yet tried.Tested on a drive
Omron 3G3MX2 (MX2-V2)USB-RS485 adapterNot yet tried on a drive
Mitsubishi FR-D700RS-485 adapterNot yet tried on a drive
Mitsubishi FR-E800PU port RJ45 through an RS-485 adapter or the ServMod BoxTested on a drive
Schneider ATV320RS-485 adapter, Modbus RTUNot yet tried on a drive
Siemens SINAMICS V20RS-485 adapter on terminals P+ and N- (6 and 7)Not yet tried on a drive
Delta MS300, INVT GD200A, ABB ACS355, Inovance MD500, Yaskawa GA500RS-485 adapter, Modbus RTUNot yet tried on a drive

More models and brands will follow. Tell us which drive you need on the requests page.

PLCs, read only

ControllerProtocolNotes
OmronFINS over UDP, port 9600DM, CIO, W, H and A areas. Types WORD, INT, DWORD, DINT, REAL, BOOL.
Allen-Bradley Logix and Micro800EtherNet/IP, port 44818Read a tag by name. Optional CPU slot for Logix.
MitsubishiMC protocolPlanned. Usually needs a port opened in GX Works.

Siemens is not supported: it needs the PUT/GET function unlocked in the controller. The PLC module is a draft and has been tested on a simulator only.

Control boards and panels

DeviceConnectionStatus
Bilwinco Q20 control boardUSB-RS232 adapter or the ServMod Box (Wi-Fi or Bluetooth)Backup and restore checked on a board
Siemens OP17 operator panelUSB-RS232 adapter on the phone or in the ServMod BoxWrite checked on spare panels

Printers

Honeywell PM45 industrial thermal label printers, over Ethernet through a USB-C Ethernet adapter. The Cable check can also test the cable between the phone and any other network device.

Adapters

  • RS-485: a USB-RS485 adapter with an FTDI, CP210x, CH34x or CH343 chip.
  • Ethernet: any USB-C Ethernet adapter. Android handles it natively.
  • One USB-C port: a phone has only one, so for Ethernet and RS-485 together use a powered USB-C hub.
  • CAN: through the ServMod Box. Lenze 8400 is tested this way.

Device pages

Wiring for each drive is on the wiring diagrams and the connection guides.