Supported equipment / Lenze 8400 StateLine C
Lenze 8400 StateLine C parameter backup and restore from an Android phone
Back up the settings of a Lenze 8400 StateLine C on your phone, then restore them to a replacement drive in minutes. No laptop, no mobile signal and no software to install on a PC.
Tested on a drive Tested on a real drive: backup, save to memory, compare, manual control and factory reset. Fault reset is not tested yet.
Download free for AndroidAll wiring diagrams
How to connect it
- ServMod Box CAN channel to the X1 terminals CH, CL and CG (CAN-High, CAN-Low, ground). Twisted pair, terminated at both ends.
Terminal names differ between production batches. Check the names printed on your unit before you wire anything, and bench-test before you touch a production machine.
What you can do with it in ServMod
- Read all parameters and save them as a backup file on the phone. Free.
- Compare a backup with a drive and see every difference. Free.
- Watch live values and fault history, and look up fault causes. Free.
- Edit parameters, restore a backup to a new drive, run the motor manually and reset faults. Part of the Pro plan.
Good to know
- Node 1, 500 kbit/s.
- Manual control needs 24 V on X5/RFR (jumper 24I to RFR).
- ServMod is an independent tool. It is not made, approved or supported by Lenze.
Using a different drive? Tell us which one you need. See also the cables and adapters you need.