Lenze 8400 StateLine C parameter backup and restore from an Android phone

Back up the settings of a Lenze 8400 StateLine C on your phone, then restore them to a replacement drive in minutes. No laptop, no mobile signal and no software to install on a PC.

Tested on a drive Tested on a real drive: backup, save to memory, compare, manual control and factory reset. Fault reset is not tested yet.

Download free for AndroidAll wiring diagrams

How to connect it

  • ServMod Box CAN channel to the X1 terminals CH, CL and CG (CAN-High, CAN-Low, ground). Twisted pair, terminated at both ends.

Terminal names differ between production batches. Check the names printed on your unit before you wire anything, and bench-test before you touch a production machine.

Wiring diagram: Lenze 8400 StateLine C, box can

What you can do with it in ServMod

  • Read all parameters and save them as a backup file on the phone. Free.
  • Compare a backup with a drive and see every difference. Free.
  • Watch live values and fault history, and look up fault causes. Free.
  • Edit parameters, restore a backup to a new drive, run the motor manually and reset faults. Part of the Pro plan.

Good to know

  • Node 1, 500 kbit/s.
  • Manual control needs 24 V on X5/RFR (jumper 24I to RFR).
  • ServMod is an independent tool. It is not made, approved or supported by Lenze.

Using a different drive? Tell us which one you need. See also the cables and adapters you need.