Supported equipment / Mitsubishi FR-D700
Mitsubishi FR-D700 parameter backup and restore from an Android phone
Back up the settings of a Mitsubishi FR-D700 on your phone, then restore them to a replacement drive in minutes. No laptop, no mobile signal and no software to install on a PC.
Not yet tried on a drive Not yet tried on a real drive.
Download free for AndroidAll wiring diagrams
How to connect it
- USB-RS485 adapter on the PU connector (RJ45): the signal pair is made by joining pins 3 and 5 and pins 4 and 6. Do not use the power pins.
- ServMod Box RS-485 channel to the same pins.
Terminal names differ between production batches. Check the names printed on your unit before you wire anything, and bench-test before you touch a production machine.
What you can do with it in ServMod
- Read all parameters and save them as a backup file on the phone. Free.
- Compare a backup with a drive and see every difference. Free.
- Watch live values and fault history, and look up fault causes. Free.
- Edit parameters, restore a backup to a new drive, run the motor manually and reset faults. Part of the Pro plan.
Good to know
- Modbus RTU. Set Pr.549 = 1 and Pr.117, then power cycle the drive.
- ServMod is an independent tool. It is not made, approved or supported by Mitsubishi.
Using a different drive? Tell us which one you need. See also the cables and adapters you need.