Allen-Bradley PowerFlex 525 fault F006: Motor stalled

The drive could not accelerate or decelerate the motor, typically because it sat in current limit too long.

What to check

  1. Increase accel time (P041, A442, A444, A446) or reduce the load so output current stays below the current limit (A484, A485)
  2. Check for an overhauling load

Source: PowerFlex 520-series User Manual (520-UM001O-EN-E, September 2025), page 161 (fault). Manufacturer page.

Keep the settings safe before you change anything

Before you reset, replace or reprogram a Allen-Bradley PowerFlex 525, save all its parameters to your phone with ServMod, so a replacement can be set up in minutes. See how to connect the Allen-Bradley PowerFlex 525 to a phone and the wiring diagrams.

Download free for Android

Other Allen-Bradley PowerFlex 525 fault codes

F002F003F004F005F006F007F008F009F012F013F015F021F029F033F038F039F040F041F042F043F048F059F063F064F070F071F072F073F080F081F082F083F091F094F100F101F105F106F107F109F110F111F114F122F125F126F127

This is a short summary written by ServMod. It can contain mistakes or be out of date. Check the manufacturer's current manual before changing settings or opening a drive. ServMod is independent and is not made, approved or supported by the manufacturer. Work on live equipment only if you are qualified, and isolate and lock out the supply first.