| Code | Name | Meaning |
|---|---|---|
| E01 | Over-current at constant speed | Output current went above the safe limit while the drive was running at steady speed (short circuit, locked... |
| E02 | Over-current during deceleration | Excess output current was detected while slowing down; output is cut. The manual gives the same cause hints... |
| E03 | Over-current during acceleration | Excess output current was detected while speeding up; output is cut. Same cause hints as E01. |
| E04 | Over-current in other conditions | Over-current occurred at a time that is not constant speed, acceleration or deceleration. Same cause hints as... |
| E05 | Motor overload (electronic thermal) | The drive's electronic thermal model decided the motor was overloaded and tripped the output. |
| E06 | Braking resistor overload | The braking-chopper duty ratio went above the limit set in b090, so the drive shut off its output. |
| E07 | Over-voltage | The DC bus voltage rose above its limit, for example from regenerative energy from the motor or a high supply... |
| E08 | EEPROM error | The built-in memory had a problem, typically due to noise or high temperature, and the output was shut off. |
| E09 | Under-voltage | The internal DC bus voltage dropped under its threshold, which can cause control faults, motor heating or... |
| E10 | Current detection error | A fault in the drive's internal current sensing circuit was detected and the output was shut off. |
| E11 | CPU error | The drive's processor malfunctioned and the output was switched off. |
| E12 | External trip | A digital input assigned to the EXT function (option 12) was activated, so the drive latched a trip. |
| E13 | Unattended start protection (USP) | Power was applied while a run command was already active and USP was enabled, so the drive refused to start. |
| E14 | Ground fault | A ground fault between the drive output and the motor was found during the power-up test. This protects the... |
| E15 | Input over-voltage | The drive checks incoming voltage after 100 seconds in stop mode and tripped because the level was too high. |
| E19 | Inverter thermal sensor error | The thermal sensor inside the power module is not connected / not being read. |
| E21 | Inverter over-temperature | The temperature of the power devices went above the allowed level, so the drive tripped. |
| E22 | CPU communication error | Communication between the drive's two processors failed. |
| E25 | Main circuit error | The drive could not confirm that its main power supply circuit was established, because of noise or a damaged... |
| E30 | Driver error | A fault in the safety protection circuit between the CPU and the output driver was detected, possibly from... |
| E35 | Thermistor trip | The motor thermistor connected to terminals 5 and L indicated an over-temperature, so the output was turned... |
| E36 | Brake error | With brake control enabled (b120 = 01) the drive did not receive the brake confirmation signal within the... |
| E37 | Safe stop | The safe-stop (GS) input was triggered when b145 is set to 01. |
| E38 | Low-speed overload | The drive detected an overload while running at very low speed and shut off the output. |
| E40 | Operator connection error | Communication between the drive and its keypad/operator failed. |
| E41 | Modbus communication error | A Modbus timeout occurred while the communication error action was set to trip (C076 = 00). |
| E43 | EzSQ invalid instruction | The stored EzSQ program is corrupt, or the PRG input was turned on when no program was downloaded. |
| E44 | EzSQ nesting count error | In the EzSQ program, subroutines, if-statements or for-next loops are nested deeper than eight levels. |
| E45 | EzSQ instruction error | The drive met a program instruction it cannot execute. |
| E50-E59 | EzSQ user trip 0 to 9 | User-defined trips raised by the EzSQ program (E50 to E59 correspond to user trip 0 to 9). |
| E60-E69 | Option board error | The drive detected an error in the option board fitted in the option slot. |
| E80 | Encoder disconnection | An encoder connection error was found: broken wiring, failed encoder, or an encoder that does not support... |
| E81 | Excessive speed | Motor speed reached or exceeded the maximum frequency (A004) multiplied by the over-speed detection level... |
| E83 | Positioning range error | The current position went outside the allowed position range set by P072 and P073. |
| E98 | Outside failure (safe stop) | Raised from the safe stop signal when b145 = 02 (outside failure). |
| E99 | Inside failure (safe stop) | Raised from the safe stop signal when b145 = 02, 03 or 05 (inside failure). |
Source: WJ200 Series Quick Reference Guide (NT3381AX, April 2016). Manufacturer page. See also the Hitachi WJ200 parameter list, the connection and backup page and the wiring diagrams.
This is a short summary written by ServMod. It can contain mistakes or be out of date. Check the manufacturer's current manual before changing settings or opening a drive. ServMod is independent and is not made, approved or supported by the manufacturer. Work on live equipment only if you are qualified, and isolate and lock out the supply first.