Hitachi WJ200 fault E04: Over-current in other conditions
Over-current occurred at a time that is not constant speed, acceleration or deceleration. Same cause hints as E01.
What to check
- Look for a shorted motor lead or phase-to-phase / phase-to-earth fault: disconnect the motor and megger the cable and motor windings
- Check that the motor shaft turns freely and the load is not jammed or overloaded
- On a dual-voltage motor, confirm the star/delta link arrangement matches the supply voltage
Source: WJ200 Series Quick Reference Guide (NT3381AX, April 2016), page 98. Manufacturer page.
Keep the settings safe before you change anything
Before you reset, replace or reprogram a Hitachi WJ200, save all its parameters to your phone with ServMod, so a replacement can be set up in minutes. See how to connect the Hitachi WJ200 to a phone and the wiring diagrams.
Other Hitachi WJ200 fault codes
E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15E19E21E22E25E30E35E36E37E38E40E41E43E44E45E50-E59E60-E69E80E81E83E98E99
This is a short summary written by ServMod. It can contain mistakes or be out of date. Check the manufacturer's current manual before changing settings or opening a drive. ServMod is independent and is not made, approved or supported by the manufacturer. Work on live equipment only if you are qualified, and isolate and lock out the supply first.