ServMod Sign in

Fault codes / Hitachi WJ200 / E35

Hitachi WJ200 fault E35: Thermistor trip

The motor thermistor connected to terminals 5 and L indicated an over-temperature, so the output was turned off.

What to check

  1. Check the motor temperature, ventilation and load
  2. Check the thermistor wiring and the PTC function setting on terminal 5 (C005 = 19)
  3. Check the thermistor calibration C085

Source: WJ200 Series Quick Reference Guide (NT3381AX, April 2016), page 99. Manufacturer page.

Keep the settings safe before you change anything

Before you reset, replace or reprogram a Hitachi WJ200, save all its parameters to your phone with ServMod, so a replacement can be set up in minutes. See how to connect the Hitachi WJ200 to a phone and the wiring diagrams.

Download free for Android

Other Hitachi WJ200 fault codes

E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15E19E21E22E25E30E35E36E37E38E40E41E43E44E45E50-E59E60-E69E80E81E83E98E99

This is a short summary written by ServMod. It can contain mistakes or be out of date. Check the manufacturer's current manual before changing settings or opening a drive. ServMod is independent and is not made, approved or supported by the manufacturer. Work on live equipment only if you are qualified, and isolate and lock out the supply first.